不同测温标准器及填充介质对消解实验仪温度测量影响的探讨 |
Discussion on the Influence of Different Temperature Detectors and Filling Medium on the Temperature Measurement of Dry Block Digesters |
|
HTML 查看全文 查看/发表评论 下载PDF阅读器 |
中文摘要: |
本文使用不同测温标准器及填充介质进行消解实验仪的温度实验,探讨不同条件下对温度测量结果的影响。经实验验证,推荐使用热电偶测温标准器进行温度测量,同时可使用填充介质作为导热辅助,以减少非紧密接触产生的误差。 |
英文摘要: |
This paper uses different temperature detectors and filling medium to do the temperature experiment of a dry block digester, and discusses the influence of the temperature measurement results in different conditions. The experiment results show that it is recommended to use thermocouple temperature detectors for temperature measurement. Meanwhile the filling medium can be used as the auxiliary heat conduction to reduce the temperature error caused by non-tight contact. |
|
中文关键词: 测温标准器 填充介质 消解实验仪 温度 |
英文关键词:temperature detector filling medium dry block digester temperature |
基金项目: |
DOI:10.11823/j.issn.1674-5795.2016.06.14 |
引用本文:李少鹏,陈成新,胡继承.不同测温标准器及填充介质对消解实验仪温度测量影响的探讨[J].计测技术,2016,36(6):. |
关闭 |