基于光纤延迟线的时间抖动测量系统
Timing jitter measurement system based on fiber delay line
  
HTML  查看全文  查看/发表评论  下载PDF阅读器
中文摘要:
      对飞秒激光器时间抖动的准确测量是推动其高精度应用的重要前提。为实现时间抖动的高精度、无参考测量,设计并搭建了一套基于光纤延迟线的测量系统。基于非对称迈克尔逊干涉仪的结构,在其中一臂引入一段长光纤延迟线鉴别时间误差,提高时间抖动测量精度。测量了一台实验室自制的重复频率为82 MHz的锁模光纤激光器的时间抖动功率谱,其在100 Hz~10 kHz的积分范围内RMS时间抖动为10.1 fs。
英文摘要:
Accurate measurement of the timing jitter of femtosecond laser is an important prerequisite to promote its high-precision application. In order to achieve high-precision and no-reference measurement of timing jitter, a measurement system based on fiber delay line was designed and built. Based on the structure of asymmetric Michelson interferometer, a long fiber delay line is added into one arm to identify the time error and improve the measurement accuracy of timing jitter. The timing jitter power spectrum of a lab-made mode-locked fiber laser with a repetition rate of 82 MHz was measured, and the RMS timing jitter was 10.1 fs in the integrated range of 100 Hz to 10 kHz.
作者单位
余泓漪, 吴言, 田昊晨, 宋有建, 胡明列 天津大学 精密仪器与光电子工程学院 光电信息技术教育部重点实验室, 天津 300072 
中文关键词:  飞秒激光器  时间抖动  光纤延迟线
英文关键词:femtosecond laser  timing jitter  fiber delay line
基金项目:
DOI:10.11823/j.issn.1674-5795.2022.05.11
引用本文:余泓漪, 吴言, 田昊晨, 宋有建, 胡明列.基于光纤延迟线的时间抖动测量系统[J].计测技术,2022,(5):.