介绍了荧光测温方法的基本原理及典型系统的组成,分析了荧光测温方法中的系统误差和随机误差的主要来源,并探讨了基于数学模型的测量不确定度评估方法,指出了在荧光测温装置的研究与应用中测量误差分析和测量不确定度评估的重要性。在测量误差分析方面,需要充分考虑装置内部参数及测量环境对荧光测温参数(如荧光寿命或荧光强度比)的影响,通过优化激发光源、荧光材料、检测器、数据采集和数据处理方案,并进行环境因素分析与校准,最大程度地降低系统误差,提高测温结果的准确性。此外,研究荧光材料发光特征随温度以外其他因素变化的物理机制,可以为开发更具适应性的荧光测温材料提供理论基础。在测量不确定度评估方面,基于荧光寿命和荧光强度比的温度测量不确定度可以通过数学模型进行描述,以温度测量不确定度为依据可指导高精度荧光测温系统的优化设计和应用。 |
英文摘要: |
In this paper, the basic principle of luminescence thermometry and the composition of typical systems are introduced, with discussion on the measurement errors and uncertainty evaluation models of luminescence thermometry. The importance of measurement error analysis and measurement uncertainty evaluation in the research and application of luminescence thermometer is pointed out. In the analysis of measurement errors, it is crucial to comprehensively consider the influence of internal device parameters and the measurement environment on luminescence thermometry parameters, such as luminescence lifetime and intensity ratio. It can significantly minimize systematic errors and enhance the accuracy of temperature measurement to optimize the excitation light source, phosphors, detectors, data acquisition, and data processing schemes, along with to conduct thorough environmental factor analysis and calibration. Furthermore, to investigate the physical mechanisms that cause variations in the emission characteristics of phosphor due to factors other than temperature can lay a theoretical foundation for developing more adaptable luminescence thermometry materials. In the evaluation of measurement uncertainty, the uncertainty in temperature measurement based on luminescence lifetime and intensity ratio can be described using mathematical models. This quantified temperature measurement uncertainty serves as a basis for guiding the optimization and application of high?precision luminescence thermometry systems. |
|
中文关键词: 荧光测温方法 荧光强度比 荧光寿命 测量误差 测量不确定度 |
英文关键词:luminescence thermometry intensity ratio decay lifetime measurement error measurement uncertainty |
基金项目: |
DOI:10.11823/j.issn.1674-5795.2024.03.02 |
引用本文:符泰然, 吴宇颂, 张常贤.荧光测温方法的测量误差与测量不确定度分析综述[J].计测技术,2024,44(3):. |
关闭 |
|
|
|